60227 IEC 06 IV (f) 300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE
CABLE STRUCTURE
Conductor : Fiexible annealed copper wire
Insulation : Polyvinyl chloride (PVC/C)
Insulation color : Black (Other colors available upon request)
TECHNICAL DATA
Classification : Maximum conductor temperature 70°C
: Circuit voltage not exceeding 300/500 Volts
Rated voltage : 300 Volts between Line to Earth
: 500 Volts between Line to Line
Ac Testing voltage : 2,000 volts
Reference standard : TIS 11 Part 3-2553 Table 7
APPLICATION
Building wiring for installation on insulator or in raceway dry location.
--------------------------------------------------------------------------------------------------------------
60227 IEC 02 THW (f) 450/750V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE
CABLE STRUCTURE
Conductor : Fiexible annealed copper wire
Insulation : Polyvinyl chloride (PVC/C)
Insulation color : Black (Other colors available upon request)
TECHNICAL DATA
Classification : Maximum conductor temperature 70°C
: Circuit voltage not exceeding 450/750 Volts
Rated voltage : 60227 IEC 06 IV (f) 300/500 V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE
CABLE STRUCTURE
Conductor : Fiexible annealed copper wire
Insulation : Polyvinyl chloride (PVC/C)
Insulation color : Black (Other colors available upon request)
TECHNICAL DATA
Classification : Maximum conductor temperature 70°C
: Circuit voltage not exceeding 300/500 Volts
Rated voltage : 300 Volts between Line to Earth
: 500 Volts between Line to Line
Ac Testing voltage : 2,000 volts
Reference standard : TIS 11 Part 3-2553 Table 7
APPLICATION
Building wiring for installation on insulator or in raceway dry location.
--------------------------------------------------------------------------------------------------------------
60227 IEC 02 THW (f) 450/750V 70°C FLEXIBLE CONDUCTOR PVC INSULATED, SINGLE CORE
CABLE STRUCTURE
Conductor : Fiexible annealed copper wire
Insulation : Polyvinyl chloride (PVC/C)
Insulation color : Black (Other colors available upon request)
TECHNICAL DATA
Classification : Maximum conductor temperature 70°C
: Circuit voltage not exceeding 450/750 Volts
Rated voltage : 450 Volts between Line to Earth
: 750 Volts between Line to Line
Ac Testing voltage : 2,000 volts
Reference standard : TIS 11 Part 3-2553 Table 3
APPLICATION
Building wiring for installation on insulator or in raceway dry location.Volts between Line to Earth
: 750 Volts between Line to Line
Ac Testing voltage : 2,000 volts
Reference standard : TIS 11 Part 3-2553 Table 3
APPLICATION
Building wiring for installation on insulator or in raceway dry location.